YAGEO Group has introduced additional capacitance options and C0G dielectric offerings in its KEMET VW80808 automotive-grade multilayer ceramic capacitor portfolio.
The expansion adds choices in 0805 and 1206 case sizes, combining flexible terminations with dielectric options for high-temperature filtering, power management and precision automotive circuits.
Key features and benefits
- Additional X8R and X8G capacitance values in the 0805 case size.
- New C0G options in 0805 and 1206 case sizes, with voltage ratings from 10 V to 1,000 V.
- X8R and X8G families supporting operation up to +150 °C.
- FT-CAP flexible termination construction with board-flex capability up to 5 mm.
- AEC-Q200 automotive qualification and compliance with VW80808 requirements.
- X7R, X8R, X8G and C0G dielectric options within the wider portfolio.
Technical highlights
Portfolio expansion and selection boundaries
The additions extend the choice of capacitance, dielectric and case size within the VW80808 family. The X8R options address power-management and filtering functions, while the X8G additions support high-temperature applications with voltage ratings extending to 100 V. The C0G additions cover precision circuit positions and higher-voltage applications.
| Expanded offering | Case sizes | Selection characteristic |
|---|---|---|
| X8R capacitance extensions | 0805 | Operation to +150 °C |
| X8G capacitance extensions | 0805 | Voltage ratings to 100 V |
| C0G additions | 0805 and 1206 | 10 V to 1,000 V |
The wider portfolio also includes X7R capacitors in EIA 0603, 0805, 1206 and 1210 case sizes. Its electrical ranges depend on the dielectric and voltage family rather than applying uniformly to every device.
| X7R family | Rated DC voltage | Capacitance range | Operating temperature |
|---|---|---|---|
| VW80808 FT-CAP | 6.3 V to 250 V | 180 pF to 10 µF | −55 °C to +125 °C |
| VW80808 high-voltage FT-CAP | 500 V to 1,000 V | 10 pF to 100 nF | −55 °C to +125 °C |
The X7R families offer capacitance tolerances of ±5%, ±10% and ±20%. Their temperature-related capacitance change is ±15%, referenced to +25 °C with no DC voltage applied. This temperature characteristic is separate from initial tolerance and changes associated with applied voltage and ageing.
Flexible terminations and board stress
The flexible termination construction limits the transfer of PCB bending stress into the ceramic body. This addresses flex cracks that can reduce insulation resistance or create a short circuit.
The up-to-5 mm board-flex capability is a mechanical test characteristic, not a permissible bending allowance for an assembled control unit. Flexible terminations do not eliminate damage under excessive handling or environmental stress. PCB support, assembly handling and the mechanical installation therefore remain part of component integration.
Dielectric choice changes the circuit fit
The X8R and X8G additions extend high-temperature selection to +150 °C. The new C0G options provide capacitance stability against temperature, applied voltage and ageing for circuits in which changes in capacitance would alter the intended response.
The choice between X8 dielectric characteristics should be made alongside capacitance, voltage rating and temperature requirements. A shared maximum operating temperature does not make the dielectric options interchangeable.
Typical applications
Power management and high-temperature control electronics
X8R options target power-management and filtering circuits. The +150 °C upper operating temperature of the X8R and X8G families supports selection for under-hood electronics and other thermally demanding automotive locations.
Target systems include powertrain control units, electric power-steering ECUs and ADAS controllers for camera, radar and lidar functions. In these assemblies, the flexible termination addresses board-flex stress while dielectric and voltage selection govern the electrical circuit position.
Precision sensing, timing and resonant circuits
The C0G additions target signal conditioning, sensing, resonant, timing and filtering circuits. Their capacitance stability is relevant where capacitance forms part of a frequency-setting or signal-processing network.
The 10 V to 1,000 V rating span extends C0G selection from lower-voltage signal paths to higher-voltage circuit positions. Selection should follow the required capacitance and operating voltage of the individual circuit rather than the maximum rating available across the family.
Converters, inverters and battery systems
Target applications include DC–DC converters, inverters, battery-management systems and onboard chargers. Filtering and snubber positions require separate consideration because dielectric behaviour and electrical stress differ between them.
The VW80808 high-voltage X7R family supports power-plane and bus filtering, inverter, DC–DC and battery-management applications. Its X7R dielectric is not recommended for AC-line filtering or pulse applications. A high DC voltage rating therefore does not establish suitability for a snubber position.
Design-in notes for engineers
- Select the complete capacitance, voltage, tolerance, dielectric and case-size combination before fixing the bill of materials. Portfolio endpoints are not interchangeable device ratings.
- Assess effective capacitance at the intended electrical and thermal operating point. For the X7R families, include voltage dependence and ageing alongside initial tolerance and temperature variation.
- Use the selected device’s outline and land pattern. Case size alone does not define component thickness or the complete assembly envelope.
- Match the soldering process to the component family and package. The VW80808 X7R families support wave or reflow soldering in 0603, 0805 and 1206 sizes; the 1210 size requires reflow soldering.
- Include PCB cleanliness and surface-arcing control in high-voltage layouts. Flux trapped beneath an MLCC can increase arcing risk.
- Treat AEC-Q200 as passive-component stress-test qualification. Final component and assembly selection should be validated under the actual operating conditions before production release.
Further reading
- YAGEO X8R & X8G VW80808 Automotive MLCCs
- MLCC and Ceramic Capacitors
- DC Bias Characteristics of Ceramic Capacitors
Source
This article is based on the YAGEO Group product announcement and official product documentation. Engineers should refer to the current manufacturer datasheet for final design and qualification.
References
- VW80808 Automotive MLCC Portfolio with New X8R, X8G and C0G Offerings, YAGEO Group.
- Flexible Termination System (FT-CAP), X7R Dielectric, 6.3–250 VDC, VW 80808 Specification, KEMET, April 24, 2026.
- Flexible Termination System (FT-CAP), High Voltage, X7R Dielectric, 500–1,000 VDC, VW 80808 Specification, KEMET, February 25, 2025.