Adding an inductor and a freewheeling path to a conventional 2:1 switched-capacitor converter changes how the flying capacitor transfers charge and how the output voltage can be controlled.
The resulting hybrid topology supports pulse-width-modulated output adjustment without the same efficiency penalty associated with reducing the output through increased effective resistance. An LTspice tutorial by Sam Ben-Yaakov illustrates the operating principle, capacitor-current behaviour and simulated performance, while leaving component-level optimization and hardware validation to the designer.
Why conventional switched-capacitor regulation costs efficiency
A conventional switched-capacitor converter can be represented by a topology-dependent target voltage followed by an equivalent internal resistance. For a 2:1 step-down topology, the target voltage is half the input voltage.
Four switches alternately connect a flying capacitor in two configurations:
- In one phase, the capacitor is connected in series with the input and delivers charge to the output.
- In the other phase, the capacitor supplies the output directly.
The equivalent resistance depends on the charging and discharging conditions. When the switching interval is long relative to the charging-path RC time constant, the capacitor approaches its final voltage during each interval. Shorter intervals produce partial charging and discharging; sufficiently short intervals produce an approximately constant current during the conduction interval.
At low switching frequency, the charge-transfer contribution to equivalent resistance depends on the reciprocal of the switching-frequency–capacitance product. Increasing frequency or flying capacitance reduces that contribution until resistance in the conducting paths becomes the dominant limitation. This does not eliminate the penalty of regulating below the topology’s target voltage. For the conventional converter’s charge-balance model, the tutorial gives:
Here, the target voltage is the ideal conversion voltage established by the topology. The expression describes the charge-transfer relationship discussed in the tutorial; additional switching and parasitic losses must also be considered. Lowering the output by increasing effective internal resistance therefore sacrifices efficiency. One example discussed is operating a transistor in its linear region rather than using it solely as an on/off switch: the output falls because more energy is dissipated in the transistor.
Operating principle of the hybrid topology
The hybrid arrangement retains the conventional 2:1 switched-capacitor network but adds an output inductor and a diode freewheeling path. The diode simplifies the simulation; a controlled switch is identified as an alternative, although its timing is not developed. The important change is that the inductor controls the current flowing through the flying capacitor during the active switching intervals. Charge transfer is no longer governed in the same way by the capacitor’s direct connection to a voltage source or another capacitor.
Three operating states explain the conversion process.
| Operating state | Charge-transfer or current path | Function |
|---|---|---|
| First active state | The flying capacitor is in series with the input, with current flowing through the inductor | Transfers energy toward the output |
| Second active state | The flying capacitor supplies the output through the inductor | Provides the complementary charge-transfer interval |
| Freewheeling state | The switched-capacitor switches are off, and inductor current continues through the diode | Allows the active intervals to be shortened for output adjustment |
During the active states, the node feeding the inductor is approximately at half the input voltage. During freewheeling, that node falls close to zero, subject to the diode voltage drop. Changing the duration of the active states changes the average voltage applied to the output stage. Regulation is therefore obtained through PWM action rather than by deliberately increasing dissipation in the switched-capacitor network.

Switching timing needs a clear definition
The LTspice example uses a timing parameter to set the nominal on-time:
Additional time is removed from the switching pulses to prevent shoot-through.
A parameter value of two corresponds to a nominal half-period active interval for each complementary switch group, before this timing reduction. Larger values shorten those active intervals and extend freewheeling. The distinction matters when interpreting the results: the duty ratio of an individual switch group is not the total fraction of a cycle during which either active charge-transfer state is present. The timing reduction also means that nominal duty ratios alone do not fully describe the simulated output voltage.
Flying-capacitor current follows the inductor
The flying capacitor conducts during the active switching intervals. Its current follows the inductor current, with opposite polarity in the charging and discharging states. This differs from the sharp charging and discharging waveforms demonstrated for the conventional circuit with a small flying capacitor. In the hybrid circuit, the inductor establishes the current trajectory during charge transfer.
The tutorial also identifies narrow transition spikes caused by diode parasitic capacitance. A zoomed simulation trace gives a pulse duration of approximately 1.6 ns. These spikes are separate from the main inductor-controlled capacitor-current waveform; their reported duration is specific to the demonstrated model.

LTspice example and simulation boundaries
The principal demonstration uses:
- Input voltage: 100 V.
- Switching frequency: 100 kHz.
- Initial flying capacitance: 1 µF.
- Initial resistive load: 20 Ω.
- Switch models with assigned on-resistance and added elements intended to represent MOSFET-related behaviour.
- Shortened switching pulses to prevent shoot-through.
For the main demonstration, the explicitly added switch-capacitance parameter is set to zero to exclude that loss contribution. Diode parasitic capacitance nevertheless remains visible in the transition-current discussion.
These are explanatory simulations, not measured prototype results or a complete efficiency model. The transcript does not provide a complete numerical component specification, including the nominal output inductance and all device-loss parameters. Consequently, the reported efficiencies should not be treated as guaranteed hardware performance.
Simulated regulation and efficiency
Output adjustment over the timing sweep
The timing parameter is swept from two to eight, using three simulated operating points. The output falls from below the nominal 50 V target to approximately 8 V. Across this sweep, the reported efficiency decreases from approximately 99.6% to approximately 95%. The useful result is not lossless regulation. It is that a substantial reduction in output voltage occurs without the proportional efficiency reduction associated with dissipative regulation of the conventional fixed-ratio converter. The timing reduction is significant: in a later comparison, the high-output hybrid operating point is described as approximately 47 V rather than 50 V.

Sensitivity to flying capacitance
A separate hybrid-converter sweep changes the flying capacitance from 1 µF to 100 µF. The reported output remains between approximately 22.13 V and 22.14 V, with very little efficiency change. The conventional converter behaves differently. With the inductor effectively removed and the conventional switching sequence restored, small capacitance produces a substantial output-voltage and efficiency reduction. Increasing capacitance toward 10 µF and 100 µF moves operation closer to the nominal 50 V target.
This comparison supports a narrower conclusion than “capacitance no longer matters”: the hybrid converter’s simulated output and efficiency are much less sensitive to flying capacitance over the tested range. It does not establish a universal minimum capacitance or eliminate the need to check capacitor voltage excursion and component stress.
Load sensitivity and effective output resistance
With the hybrid converter’s resistive load changed from 20 Ω to 100 Ω, the reported output rises slightly, from approximately 22.1 V to 22.3 V. Efficiency changes from approximately 98% to 97%, a decrease of about one percentage point. A further simulation uses current-source loading to determine effective output resistance from the voltage change associated with a load-current change.
| Current-loaded comparison | Conventional converter | Hybrid converter |
|---|---|---|
| Flying capacitance | 1 µF | 1 µF |
| Output-voltage reduction for a 1 A current increase | 2.47 V | 91 mV |
| Reported effective output resistance | 2.47 Ω | 91 mΩ |
| Additional lower-output operating point | Not demonstrated in this comparison | Approximately 91 mΩ again with the timing parameter set to six |
For the conventional converter, the current sweep from 1 A to 4 A is accompanied by an efficiency reduction from approximately 97% to 80%. The hybrid results demonstrate a much smaller voltage change with load in the illustrated model. They are static simulation comparisons, however, and do not establish closed-loop transient response or control-loop stability.

Design-in notes for engineers
The following points are editorial validation guidance, not additional performance claims or specifications from the tutorial.
- Treat the 1 µF result as a demonstrated simulation point, not a generally applicable capacitor recommendation.
- Check flying-capacitor voltage excursion and current over the complete input, output and load range before selecting capacitance.
- Define timing explicitly: distinguish each switch group’s on-time, total active time, intentional freewheeling and shoot-through-prevention intervals.
- Reproduce the current waveforms before using the simulated efficiency figures as a design target.
- Extend the model to include the actual switches, diode or synchronous freewheeling switch, gate drive, passive-component losses and interconnect parasitics.
- Verify the inductor’s operating current waveform and thermal margin. The transcript does not supply enough numerical information to select a production inductor.
- Check startup, flying-capacitor voltage balance, overload and load transients separately; these are not established by the steady-state sweeps.
- Validate transition spikes and EMI in hardware rather than assuming that the simulated narrow pulses are insignificant in every implementation.
- For purchasing comparisons, assess the complete capacitor–inductor–semiconductor solution. The tutorial does not establish a cost, footprint or reliability advantage for a specific component technology.
Limits and trade-offs
Reduced capacitance sensitivity does not remove component constraints
The hybrid topology changes the charge-transfer mechanism, but the tutorial does not establish an unrestricted reduction in flying capacitance. Its capacitance sweep covers 1 µF to 100 µF under the demonstrated conditions. No capacitor dielectric, package, voltage rating or manufacturer series is specified. The simulation therefore cannot support a recommendation for a particular capacitor construction or part number.
The inductor becomes part of the conversion mechanism
The output inductor is not merely an optional filter added to an otherwise unchanged converter. It shapes the charge-transfer current and works with the freewheeling path to support PWM output adjustment. That benefit comes with an additional magnetic component and a requirement to evaluate its losses and operating limits. The tutorial does not quantify the resulting size, cost or thermal trade-off.
A synchronous alternative needs its own validation
Replacing the freewheeling diode with a controlled switch is identified as an option. However, the tutorial deliberately uses a diode to avoid developing the additional switch timing. A synchronous implementation should therefore be treated as a separate design exercise, not as a validated extension with an established efficiency improvement.
The demonstrations are not a complete regulated power supply
The timing sweeps show that the output voltage can be adjusted. They do not establish a complete feedback controller, compensation design, protection strategy or response to dynamic disturbances. Likewise, the high simulated efficiency does not establish soft switching or eliminate the switching-loss mechanisms discussed earlier.
Conclusion
The hybrid topology addresses a central limitation of conventional fixed-ratio switched-capacitor conversion: reducing output voltage through increased effective resistance also reduces efficiency.
Adding an inductor and a freewheeling path enables a different approach. The inductor shapes flying-capacitor current, while shortened active intervals provide PWM output adjustment. The LTspice examples demonstrate reduced sensitivity to flying capacitance, low effective output resistance and a relatively modest simulated efficiency reduction across a substantial output-voltage range.
For practical implementation, the next engineering task is to validate the complete loss model, switching sequence and passive-component stresses—not to adopt the illustrative efficiency figures as finished-design specifications.
Further reading
- Inductance, Impedance, Q Factor and DCR Losses
- Power Inductors and Storage Chokes
- Storage Inductors Selection for DC/DC Converters
Source
Adapted from Sam Ben-Yaakov’s technical tutorial published on November 20, 2026. Numerical results are LTspice simulation examples described in the video, not hardware measurements.